Heat output, tubing, loops and planning cost

Radiant Floor Heating Calculator

Estimate radiant-floor heat output, tubing length, loop count and material cost from heated area, coverage percentage, tubing spacing, routing allowance and maximum loop length.

Imperial and metric Rounded purchase quantities Cost estimate

Default project preview

6 loops

Heated floor area

1,080 ft²

Planning heat output

27,000 BTU/h

Tubing before allowance

1,440 ft

Average tubing per loop

264 ft

Calculator

Build the material order

Your order will appear here

Enter the project details and calculate a rounded material estimate.

Input and output guide

What each value means

The labels and units below are part of this calculator’s visible methodology. Replace every default with measurements or product data from the actual project.

Total floor area

Enter this project assumption in ft². The current imperial default is 1200 ft².

Heated floor percentage

Enter this project assumption in %. The current imperial default is 90 %. Minimum: 1. Maximum: 100.

Planning heat output

Enter this project assumption in BTU/h·ft². The current imperial default is 25 BTU/h·ft².

Tubing spacing

Enter this project assumption in in. The current imperial default is 9 in.

Routing and leader allowance

Enter this project assumption in %. The current imperial default is 10 %. Minimum: 0. Maximum: 50.

Maximum tubing per loop

Enter this project assumption in ft. The current imperial default is 300 ft.

Tubing price

Enter this project assumption in per ft. The current imperial default is 0.75 per ft. Minimum: 0.

Manifold and loop hardware per loop

Enter this project assumption in a unitless value. The current imperial default is 85. Minimum: 0.

How to read the outputs

Heated floor area

90% of total area. Default preview: 1,080 ft².

Planning heat output

entered area output rate. Default preview: 27,000 BTU/h.

Tubing before allowance

area divided by spacing. Default preview: 1,440 ft.

Average tubing per loop

evenly distributed estimate. Default preview: 264 ft.

Equivalent heat output

thermal output equivalent. Default preview: 7.91 kW.

Planning material cost

tubing and entered loop hardware. Default preview: $1,698.00.

Methodology

Transparent calculation

BuildMeter converts every input to a consistent internal unit, applies the selected allowance, and rounds products up to whole purchasable units.

Base tubing length ≈ heated area ÷ tubing spacing. Routing allowance is added, then total tubing is divided by maximum loop length and rounded up. Heat output = heated area × entered output rate.

Related tools

Continue planning the project

BuildMeter Guides

Understand the measurements and assumptions

Use these visible reference guides before changing project inputs or planning allowances.

FAQ

Radiant Floor Heating Calculator questions

Why exclude some floor area?+

Permanent cabinets, tubs and other areas may not receive tubing, depending on the system design.

Does shorter spacing increase tubing length?+

Yes. Closer spacing places more tubing in the same floor area.

Does this size the boiler or heat pump?+

No. Equipment sizing requires a room-by-room heat-loss calculation and system design.

Built and reviewed by Liron Elimeleh

Liron Elimeleh, software engineer and founder of BuildMeter, develops the calculation logic, unit conversions, validation and visible assumptions. ELStudios maintains the source and public correction history.