Required airflow, fan count and energy cost

Whole House Fan Size Calculator

Estimate whole-house fan airflow from building volume and target air changes, then compare installed fan capacity and operating cost.

Imperial and metric Rounded purchase quantities Cost estimate

Default project preview

4,800 CFM

Required per fan

4,800 CFM

Installed capacity

5,000 CFM

Capacity margin

+200 CFM

One air change

2.88 min

Calculator

Build the material order

Your order will appear here

Enter the project details and calculate a rounded material estimate.

Input and output guide

What each value means

The labels and units below are part of this calculator’s visible methodology. Replace every default with measurements or product data from the actual project.

Conditioned floor area

Enter this project assumption in ft². The current imperial default is 1800 ft².

Average ceiling height

Enter this project assumption in ft. The current imperial default is 8 ft.

Target air changes

Enter this project assumption in ACH. The current imperial default is 20 ACH.

Fan count

Enter this project assumption in a unitless value. The current imperial default is 1. Minimum: 1.

Rated capacity per fan

Enter this project assumption in CFM. The current imperial default is 5000 CFM.

Power per fan

Enter this project assumption in W. The current imperial default is 600 W.

Operating time

Enter this project assumption in hours/day. The current imperial default is 4 hours/day. Minimum: 0. Maximum: 24.

Electricity price

Enter this project assumption in per kWh. The current imperial default is 0.18 per kWh. Minimum: 0.

How to read the outputs

Required per fan

1 fan. Default preview: 4,800 CFM.

Installed capacity

entered ratings. Default preview: 5,000 CFM.

Capacity margin

above target. Default preview: +200 CFM.

One air change

at installed capacity. Default preview: 2.88 min.

Daily electricity

4 operating hours. Default preview: 2.4 kWh.

Daily energy cost

entered electricity rate. Default preview: $0.43.

Methodology

Transparent calculation

BuildMeter converts every input to a consistent internal unit, applies the selected allowance, and rounds products up to whole purchasable units.

Building volume = floor area × average ceiling height. Required airflow = volume × target ACH ÷ 60 for CFM, or volume × ACH for m³/h.

Reviewed project guidance

How to use this estimate in a real project

Last reviewed: August 19, 2026

Estimate required whole-house-fan airflow from building volume and target air changes, compare installed fan capacity, and estimate operating energy/cost.

Calculation steps

  1. 1Multiply conditioned floor area by average ceiling height for building volume.
  2. 2Multiply volume by target ACH and divide by 60 to obtain required CFM.
  3. 3Compare the required airflow with total rated capacity of the selected fans.
  4. 4Use fan watts and runtime to estimate electricity use independently of airflow.

Worked numerical example

An 1,800 ft² home with 8 ft average ceilings contains 14,400 ft³. At a target 20 air changes per hour, required airflow is 4,800 CFM. One 5,000 CFM fan slightly exceeds that entered target.

Purchasing and rounding

Fan capacity must be coordinated with adequate open-window area, attic exhaust, noise goals, controls and safe combustion-appliance operation. Follow manufacturer installation requirements.

Interpret the result

The result compares an entered ACH target with rated fan airflow. It does not guarantee comfort, cooling effectiveness or safe building pressure under all operating conditions.

Page-specific assumptions

  • Average ceiling height reasonably represents building volume.
  • Rated fan capacities can be summed.
  • Target ACH is selected for the intended operating strategy.

Common mistakes

  • Running a large fan without sufficient makeup-air openings.
  • Ignoring required attic exhaust area.
  • Treating outdoor air temperature/humidity as irrelevant to operation.

Primary and technical references

BuildMeter provides planning estimates, not engineering, architectural, electrical, mechanical, plumbing, permit or code approval. Review the methodology and verify final decisions with product documentation and qualified professionals.

Related tools

Continue planning the project

FAQ

Whole House Fan Size Calculator questions

Why does a whole-house fan need attic exhaust area?+

Supply air entering the attic must have a safe path outdoors to prevent excessive pressure.

Can the fan run with closed windows?+

Operating instructions usually require suitable open inlets; follow the manufacturer and installer guidance.

Does this replace HVAC cooling?+

No. It exchanges indoor air with outdoor air and works only when outdoor conditions are suitable.

Built and reviewed by Liron Elimeleh

Liron Elimeleh, software engineer and founder of BuildMeter, develops the calculation logic, unit conversions, validation and visible assumptions. ELStudios maintains the source and public correction history.

Individual editorial review completed: August 19, 2026