Peak demand, recovery and tank capacity

Water Heater Size Calculator

Create a preliminary storage water-heater estimate from peak shower demand, other hot-water use, recovery rate, reserve and temperature rise.

Imperial and metric Rounded purchase quantities Cost estimate

Default project preview

40 gallons

Shower demand

40 gal

Recovery credit

20 gal/hr

First-hour guide

60 gal

Storage requirement

35 gal

Calculator

Build the material order

Your order will appear here

Enter the project details and calculate a rounded material estimate.

Input and output guide

What each value means

The labels and units below are part of this calculator’s visible methodology. Replace every default with measurements or product data from the actual project.

Showers in peak hour

Enter this project assumption in a unitless value. The current imperial default is 2. Minimum: 0.

Minutes per shower

Enter this project assumption in min. The current imperial default is 10 min.

Shower flow

Enter this project assumption in gal/min. The current imperial default is 2 gal/min.

Other peak-hour hot water

Enter this project assumption in gal. The current imperial default is 10 gal. Minimum: 0.

Heater recovery in one hour

Enter this project assumption in gal. The current imperial default is 20 gal. Minimum: 0.

Demand reserve

Enter this project assumption in %. The current imperial default is 10 %. Minimum: 0. Maximum: 50.

Required temperature rise

Enter this project assumption in °F. The current imperial default is 70 °F.

Heating efficiency

Enter this project assumption in %. The current imperial default is 90 %. Minimum: 1. Maximum: 100.

Energy price

Enter this project assumption in per kWh. The current imperial default is 0.18 per kWh. Minimum: 0.

How to read the outputs

Shower demand

2 showers. Default preview: 40 gal.

Recovery credit

entered heater recovery. Default preview: 20 gal/hr.

First-hour guide

tank plus entered recovery. Default preview: 60 gal.

Storage requirement

before standard-size rounding. Default preview: 35 gal.

Peak heating energy

thermal input adjusted for efficiency. Default preview: 10.5 kWh.

Peak energy cost

entered energy rate. Default preview: $1.88.

Methodology

Transparent calculation

BuildMeter converts every input to a consistent internal unit, applies the selected allowance, and rounds products up to whole purchasable units.

Peak demand = shower count × duration × flow + other demand, with reserve. Storage need = peak demand − one-hour recovery, rounded up to a planning tank size.

Reviewed project guidance

How to use this estimate in a real project

Last reviewed: July 29, 2026

This calculator estimates storage or first-hour demand from household fixtures and usage assumptions. It is useful for comparing scenarios, but final selection must consider recovery rate, fuel, incoming-water temperature and simultaneous demand.

Calculation steps

  1. 1List hot-water uses during the busiest hour.
  2. 2Estimate actual hot-water volume rather than total mixed water.
  3. 3Add simultaneous fixture demand.
  4. 4Compare demand with published first-hour rating or recovery performance.

Worked numerical example

If the peak hour includes two 20-gallon showers, 8 gallons of sink use and 7 gallons for a dishwasher, the gross peak demand is 55 gallons before accounting for mixed-water temperature and recovery.

Purchasing and rounding

Storage volume and first-hour rating are different. Compare the calculator result with the certified performance of the exact heater, not tank gallons alone.

Interpret the result

A larger tank can buffer peaks; a faster heater can recover sooner. The best choice depends on both demand pattern and energy source.

Page-specific assumptions

  • Peak-hour use is represented by entered fixtures.
  • Incoming and delivery temperatures are considered separately if needed.
  • No unusual process loads.
  • Distribution losses are not hidden in fixture volume.

Common mistakes

  • Sizing only by number of bedrooms.
  • Comparing tank volume instead of first-hour rating.
  • Using total shower water as 100% hot water.
  • Ignoring recovery at winter inlet temperature.

Primary and technical references

BuildMeter provides planning estimates, not engineering, architectural, electrical, mechanical, plumbing, permit or code approval. Review the methodology and verify final decisions with product documentation and qualified professionals.

Related tools

Continue planning the project

FAQ

Water Heater Size Calculator questions

What is first-hour rating?+

It describes how much hot water a storage heater can deliver during a high-demand first hour, combining stored water and recovery.

Why does incoming-water temperature matter?+

Colder incoming water requires more energy and can reduce recovery performance.

Can this size a tankless heater?+

Not directly. Tankless systems are selected by simultaneous flow and required temperature rise rather than storage volume.

Built and reviewed by Liron Elimeleh

Liron Elimeleh, software engineer and founder of BuildMeter, develops the calculation logic, unit conversions, validation and visible assumptions. ELStudios maintains the source and public correction history.

Individual editorial review completed: July 29, 2026

About the author