Tilt geometry, shadow clearance, array depth and modules

Solar Panel Row Spacing Calculator

Estimate minimum solar-row pitch, clear gap between rows, total array depth, modules per row and module cost from panel dimensions, tilt and design sun elevation.

Imperial and metric Rounded purchase quantities Cost estimate

Default project preview

13.33 ft

Panel vertical rise

2.87 ft

Horizontal panel projection

6.16 ft

Shadow-clearance component

6.16 ft

Total array depth

46.14 ft

Calculator

Build the material order

Your order will appear here

Enter the project details and calculate a rounded material estimate.

Input and output guide

What each value means

The labels and units below are part of this calculator’s visible methodology. Replace every default with measurements or product data from the actual project.

Usable width of each row

Enter this project assumption in ft. The current imperial default is 60 ft.

Panel width across the row

Enter this project assumption in ft. The current imperial default is 3.7 ft.

Panel length in tilt direction

Enter this project assumption in ft. The current imperial default is 6.8 ft.

Gap between panels in a row

Enter this project assumption in in. The current imperial default is 1 in. Minimum: 0.

Panel tilt angle

Enter this project assumption in degrees. The current imperial default is 25 degrees. Minimum: 0. Maximum: 80.

Design sun elevation

Enter this project assumption in degrees. The current imperial default is 25 degrees. Minimum: 1. Maximum: 89.

Additional service clearance

Enter this project assumption in ft. The current imperial default is 1 ft. Minimum: 0.

Number of panel rows

Enter this project assumption in a unitless value. The current imperial default is 4. Minimum: 1.

Price per panel

Enter this project assumption in a unitless value. The current imperial default is 240. Minimum: 0.

How to read the outputs

Panel vertical rise

25° tilt. Default preview: 2.87 ft.

Horizontal panel projection

plan depth of one row. Default preview: 6.16 ft.

Shadow-clearance component

25° design sun elevation. Default preview: 6.16 ft.

Total array depth

4 rows with entered service clearance. Default preview: 46.14 ft.

Panel layout

60 ft usable row width. Default preview: 15 per row / 60 total.

Panel cost

modules only. Default preview: $14,400.00.

Methodology

Transparent calculation

BuildMeter converts every input to a consistent internal unit, applies the selected allowance, and rounds products up to whole purchasable units.

Panel rise = panel length × sin(tilt). Shadow-clear gap = rise ÷ tan(design sun elevation). Row pitch adds panel projection and service clearance; total array depth repeats that geometry across rows.

Related tools

Continue planning the project

FAQ

Solar Panel Row Spacing Calculator questions

What design sun elevation should be used?+

Choose a project-specific seasonal design condition based on site latitude, orientation and acceptable shading rather than relying on a universal value.

Does this account for terrain slope?+

No. Sloped or uneven sites change relative row elevation and shadow geometry.

Why add service clearance?+

A geometric no-shadow gap may still be too narrow for access, drainage, vegetation control or equipment maintenance.