Air changes, duty cycle, energy and cost

Ventilation Fan Runtime Calculator

Estimate how many minutes per hour a ventilation fan must run to achieve a target air-change rate, plus daily energy use and cost.

Imperial and metric Rounded purchase quantities Cost estimate

Default project preview

38.1 minutes/hour

Room volume

2,700 ft³

Required average airflow

135 CFM

Delivered fan airflow

212.5 CFM

Continuous-fan ACH

4.72

Calculator

Build the material order

Your order will appear here

Enter the project details and calculate a rounded material estimate.

Input and output guide

What each value means

The labels and units below are part of this calculator’s visible methodology. Replace every default with measurements or product data from the actual project.

Room length

Enter this project assumption in ft. The current imperial default is 20 ft.

Room width

Enter this project assumption in ft. The current imperial default is 15 ft.

Room height

Enter this project assumption in ft. The current imperial default is 9 ft.

Target air changes per hour

Enter this project assumption in ACH. The current imperial default is 3 ACH.

Fan airflow

Enter this project assumption in CFM. The current imperial default is 250 CFM.

Delivered airflow efficiency

Enter this project assumption in %. The current imperial default is 85 %. Minimum: 1. Maximum: 100.

Fan electrical power

Enter this project assumption in W. The current imperial default is 90 W.

Hours ventilation is required

Enter this project assumption in hours/day. The current imperial default is 12 hours/day. Minimum: 0. Maximum: 24.

Electricity price

Enter this project assumption in per kWh. The current imperial default is 0.18 per kWh. Minimum: 0.

How to read the outputs

Room volume

entered dimensions. Default preview: 2,700 ft³.

Required average airflow

3 ACH target. Default preview: 135 CFM.

Delivered fan airflow

85% efficiency. Default preview: 212.5 CFM.

Continuous-fan ACH

at delivered airflow. Default preview: 4.72.

Daily electricity

7.62 run hours/day. Default preview: 0.686 kWh.

Daily energy cost

entered electricity rate. Default preview: $0.12.

Methodology

Transparent calculation

BuildMeter converts every input to a consistent internal unit, applies the selected allowance, and rounds products up to whole purchasable units.

Required average airflow = room volume × target ACH ÷ 60. Runtime fraction = required airflow ÷ delivered fan airflow. Daily energy = watts × runtime hours ÷ 1000.

Reviewed project guidance

How to use this estimate in a real project

Last reviewed: July 30, 2026

Estimate fan operating hours and energy use needed to deliver a target daily ventilation volume at an entered airflow.

Calculation steps

  1. 1Set the target outdoor-air volume or equivalent runtime requirement.
  2. 2Enter delivered fan airflow.
  3. 3Divide required volume by airflow.
  4. 4Calculate electricity from fan watts and operating hours.

Worked numerical example

A 60 cfm fan delivering 7,200 ft³ per day must run 120 minutes daily. At 35 W, that is 0.07 kWh per day before control losses.

Purchasing and rounding

Use controls designed for the ventilation strategy and verify measured airflow after installation.

Interpret the result

Runtime arithmetic does not establish the required ventilation rate or account for infiltration credit.

Page-specific assumptions

  • Constant delivered airflow.
  • No simultaneous boost mode.
  • Fan wattage is representative.

Common mistakes

  • Using nameplate rather than measured airflow.
  • Confusing cfm with cubic feet per day.
  • Ignoring intermittent-control requirements.

Primary and technical references

BuildMeter provides planning estimates, not engineering, architectural, electrical, mechanical, plumbing, permit or code approval. Review the methodology and verify final decisions with product documentation and qualified professionals.

Related tools

Continue planning the project

BuildMeter Guides

Understand the measurements and assumptions

Use these visible reference guides before changing project inputs or planning allowances.

FAQ

Ventilation Fan Runtime Calculator questions

What happens when runtime exceeds 60 minutes per hour?+

The entered fan is too small to reach the target air-change rate even when running continuously.

Why include delivered airflow efficiency?+

Duct resistance, grilles and installation conditions often reduce airflow below the fan free-air rating.

Is intermittent operation always acceptable?+

No. Required ventilation schedules and moisture control depend on the room use, contaminants and applicable standards.

Built and reviewed by Liron Elimeleh

Liron Elimeleh, software engineer and founder of BuildMeter, develops the calculation logic, unit conversions, validation and visible assumptions. ELStudios maintains the source and public correction history.

Individual editorial review completed: July 30, 2026