Connected watts, loss allowance and standard transformer size

Landscape Lighting Transformer Calculator

Estimate a preliminary low-voltage landscape-lighting transformer size, load utilization, annual energy use and transformer planning cost.

Imperial and metric Rounded purchase quantities Cost estimate

Default project preview

150 W

Fixture connected load

108 W

Total connected load

108 W

Loss-adjusted load

118.8 W

Selected-load utilization

79.2%

Calculator

Build the material order

Your order will appear here

Enter the project details and calculate a rounded material estimate.

Input and output guide

What each value means

The labels and units below are part of this calculator’s visible methodology. Replace every default with measurements or product data from the actual project.

Light fixtures

Enter this project assumption in a unitless value. The current imperial default is 18. Minimum: 1.

Watts per fixture

Enter this project assumption in W. The current imperial default is 6 W.

Additional connected load

Enter this project assumption in W. The current imperial default is 0 W. Minimum: 0.

Cable and driver loss allowance

Enter this project assumption in %. The current imperial default is 10 %. Minimum: 0. Maximum: 50.

Future spare capacity

Enter this project assumption in %. The current imperial default is 25 %. Minimum: 0. Maximum: 100.

Transformer price allowance

Enter this project assumption in per W. The current imperial default is 0.8 per W. Minimum: 0.

Operating hours per night

Enter this project assumption in h. The current imperial default is 5 h. Minimum: 0. Maximum: 24.

Electricity price

Enter this project assumption in per kWh. The current imperial default is 0.18 per kWh. Minimum: 0.

How to read the outputs

Fixture connected load

18 fixtures × 6 W. Default preview: 108 W.

Total connected load

fixtures plus additional load. Default preview: 108 W.

Loss-adjusted load

10% allowance. Default preview: 118.8 W.

Selected-load utilization

loss-adjusted load ÷ selected size. Default preview: 79.2%.

Annual fixture energy

5 hours per night. Default preview: 197.1 kWh.

Transformer and annual energy

entered planning rates. Default preview: $120.00 + $35.48/yr.

Methodology

Transparent calculation

BuildMeter converts every input to a consistent internal unit, applies the selected allowance, and rounds products up to whole purchasable units.

Connected load = fixture count × watts per fixture + other load. Loss and spare-capacity allowances are applied, then the result is rounded up to a common transformer size.

Related tools

Continue planning the project

FAQ

Landscape Lighting Transformer Calculator questions

Why include cable and driver losses?+

The transformer supplies more than the fixture nameplate load because wiring and electronic components consume some power.

Why add spare capacity?+

A reserve allows modest future fixture additions and keeps the transformer from being planned at its exact calculated demand.

Does transformer wattage solve voltage drop?+

No. Voltage drop also depends on cable gauge, current, run length, branching and transformer taps.